Sterimed Suction Catheter Thumb Control (SMD 700P) (FG - 16)

Mkt: Sterimed Medical Devices Pvt Ltd Country of Origin: India
₹36.75
MRP ₹75.00 Save 51 %
Inclusive of all taxes
This product cannot be returned for a refund or exchange.

PRODUCT VARIANTS

SIZE: FG 16

Sterimed Suction Catheter Thumb Control (SMD 700P) (FG - 16) ₹36.75
MRP ₹75.00 Save 51 %

Expiry on or after

Pincode

Default Discount Offer Applied
You get 51% OFF on this product
Happy Customers 9M+ Happy Customers
Authentic Products 100% Authentic
Best Quality Quality Checked Products

Similar Products

Description

Key Benefits

How to use

Safety Information/Precaution

Other Information

The Sterimed Suction Catheter with Thumb Control is a medical device intended for the removal of secretions from a patient's mouth, trachea, and bronchial tubes. It is designed for transient use by trained healthcare professionals to help maintain a clear airway in patients who are unable to clear secretions on their own. Made from non-toxic, medical-grade PVC, this catheter is developed to ensure patient safety and reduce irritation. The thumb control mechanism allows for regulated and intermittent suctioning.


Thumb Control Port: Allows the healthcare provider to precisely manage the application of suction by covering and uncovering the port, offering controlled secretion removal.
Medical-Grade PVC Construction: Fabricated from non-toxic, non-irritant medical-grade PVC material, which is flexible to navigate the airway while minimizing the risk of patient discomfort or trauma.
Universal Connector: The proximal end features a universal funnel-shaped connector to ensure compatibility and a secure connection with standard suction machine tubing.
Atraumatic Tip and Lateral Eye: Features a smooth, rounded tip and a lateral eye at the distal end to facilitate gentle insertion and allow for efficient suctioning of fluids and secretions.
Sterile and Single-Use: Each catheter is supplied in a sterile, individually sealed blister pack to prevent cross-contamination and is intended for single use only.


Q: Is this catheter intended for single use?

A: Yes, this is a sterile, single-use catheter and should be discarded after one use to prevent cross-contamination.


Q: What is the main purpose of the Sterimed Suction Catheter?

A: It is used for the removal of secretions, such as mucus or saliva, from a patient's mouth, trachea, and bronchial tubes to help keep the airway clear.


Q: How does the thumb control feature work?

A: The thumb control valve allows the person operating it, typically a healthcare professional, to start and stop the suction pressure as needed for a more controlled procedure.


Q: What does the 'FG-16' size indicate?

A: The 'FG-16' refers to the size of the catheter in French Gauge, which denotes its outer diameter. The FG-16 size has an orange color-coded connector for easy identification.


Q: Who should use this medical device?

A: This suction catheter is intended for use in medical settings like hospitals and clinics by qualified healthcare professionals. It is advisable to consult a healthcare provider for proper usage instructions.

Helps in maintaining airway patency by dependably clearing secretions from the oro-bronchial region.
The thumb control feature provides practitioners with direct regulation over the suction pressure, enhancing procedural safety.
Constructed from biocompatible materials to reduce the likelihood of mucosal trauma or irritation during use.
The universal connector design allows for straightforward and secure attachment to common suction sources in a clinical setting.
Being sterile and disposable, it supports infection control protocols by preventing cross-contamination between patients.

This device is intended for use by trained and registered healthcare professionals only.
Connect the universal connector of the catheter to the suction machine's tubing.
Gently insert the catheter into the patient's airway (oral/nasal cavity or tracheal tube) to the required depth without applying suction.
Apply intermittent suction by placing your thumb over the control port while slowly withdrawing the catheter.
The maximum duration for a single suction pass should be limited, typically not exceeding 15 seconds, to minimize the risk of hypoxia.
After use, discard the catheter as per medical waste disposal guidelines. Do not re-sterilize or reuse.

For single use only. Do not clean, re-sterilize, or reuse, as this may lead to infection or device malfunction.
Always use the correct size catheter for the patient to avoid injury.
The procedure should be performed by a qualified healthcare professional.
Prolonged suctioning can lead to hypoxia, bradycardia, and other complications; monitor the patient continuously.
Do not use if the individual sterile package is open or damaged.
Store in a cool, dry place, away from direct sunlight and heat.
Do not use if the patient has a known sensitivity or allergy to PVC materials.

Brand: Sterimed
Model: Suction Catheter Thumb Control (SMD 700P / SMD 700 ATC)
Size: FG-16 (French Gauge), indicated by an orange color-coded connector.
Material: Medical Grade PVC.
Packaging: Sterile, individually packed in a blister pack.

N/A
    Net Qty
    1N N
    Shelf Life
    60
    Item Weight
    100 g
    No. of Units in a Kit
    1
    Hsn Code
    90183990
Disclaimer:

The contents of this website are for informational purposes only and not intended to be a substitute for professional medical advice, diagnosis, or treatment. Please seek the advice of a physician or other qualified health provider with any questions you may have regarding a medical condition. Do not disregard professional medical advice or delay in seeking it because of something you have read on this website.