The Sterimed 2 Way Silicon Foley Catheter is a medical device designed for individuals requiring urinary drainage. Made from 100% medical-grade silicone, this catheter is biocompatible, which may reduce the likelihood of irritation. It is an indwelling catheter intended for both short and long-term use, featuring a two-way design with separate channels for urine drainage and balloon inflation to hold it securely in the bladder. The clear design allows for easy monitoring.
100% Medical-Grade Silicone: Constructed from biocompatible and hypoallergenic material to minimize irritation and allergic reactions during use. Two-Way Design: Features dual channels, one for urinary drainage and another for inflating the integrated balloon, which ensures the catheter remains securely in place. Smooth, Low-Friction Surface: The catheter has a smooth surface and tip, designed to facilitate easier insertion and removal, potentially reducing trauma to the urethra. Radiopaque Line: A line that is visible on X-rays is included to allow healthcare professionals to confirm the accurate placement of the catheter. Tear-Resistant Balloon: The highly elastic silicone balloon is designed for reliability and secure placement with minimal discomfort.
Q: What is a 2-way Foley catheter?
A: A 2-way Foley catheter has two channels: one for draining urine from the bladder and a second for inflating a small balloon at the tip with sterile water to hold the catheter securely in place.
Q: What is the benefit of a silicone catheter?
A: This catheter is made from 100% medical-grade silicone, which is biocompatible and hypoallergenic, making it suitable for individuals with latex allergies and for long-term use as it may reduce the risk of irritation.
Q: What does the 'FR-10' size indicate?
A: The 'FR' stands for French scale, which is a common unit for measuring the outer diameter of a catheter. '10' indicates the specific size, which is on the smaller side of the scale.
Q: How is this catheter used?
A: This device is intended for urinary drainage. It is inserted into the bladder, typically by a healthcare professional, to allow urine to flow out.
Q: Why is consulting a healthcare professional necessary?
A: Catheterization is a medical procedure that should be performed by a trained professional to ensure correct placement, minimize discomfort, and reduce the risk of complications like infections or tissue trauma.
Designed for Patient Comfort: The soft, flexible, and self-lubricated silicone construction is intended to minimize discomfort during insertion, removal, and long-term wear. Supports Continuous Drainage: Provides a reliable method for bladder drainage for patients with urinary retention or post-surgery, helping to prevent complications. Reduces Risk of Trauma: The smooth surface and flexible material are designed to lessen trauma to the urethral tissue during catheterization. Facilitates Bladder Health: Some models include a flow control clamp, which may help in exercising the bladder muscles by allowing intermittent drainage. Biocompatible for Extended Use: Made of medical-grade silicone, making it suitable for patients who require catheterization for an extended period.
This product must be used by or under the supervision of a qualified healthcare professional. 1. Before use, visually inspect the sterile package and the catheter to ensure there are no imperfections. 2. Use an aseptic technique and sterile gloves. Thoroughly clean the patient's genital area. 3. Lubricate the catheter tip with a water-based lubricant before insertion. 4. Gently insert the catheter fully into the urethra until it reaches the bladder. 5. Once urine begins to flow, insert it a little further to ensure the balloon is beyond the bladder neck. 6. Inflate the balloon using a syringe with the recommended amount of sterile water. Do not overinflate. 7. Connect the catheter's drainage port to a urine collection bag.
For single use only. Do not reuse or re-sterilize, as it may lead to infection or malfunction. Do not use if the individual package is opened or damaged. To be used only by a trained medical professional. Consult a healthcare provider before use, especially for patients with known silicone allergies, urethral strictures, or acute urethritis. The balloon should only be inflated after proper insertion into the bladder to avoid urethral injury. If you experience any discomfort, pain, or signs of a urinary tract infection, consult a doctor immediately. Store in a cool, dry place away from direct sunlight.
This catheter is sterile unless the individual packaging is opened or broken. It is made from 100% medical-grade silicone. The product is available in various sizes (French gauge) to suit different patient requirements. The injection port is typically color-coded according to its size. Some versions are MR Conditional, meaning a patient can be scanned in an MR system under specific conditions.
The contents of this website are for informational purposes only and not intended to be a substitute for professional medical advice, diagnosis, or treatment. Please seek the advice of a physician or other qualified health provider with any questions you may have regarding a medical condition. Do not disregard professional medical advice or delay in seeking it because of something you have read on this website.