Polymed Endotracheal Tube Plain (5.0 mm) 1's
PRODUCT VARIANTS
Expiry on or after
Pincode
Similar Products
Frequently bought together
The Polymed Endotracheal Tube Plain is a medical device designed for airway management during anesthesia or mechanical ventilation. It is a flexible, uncuffed tube inserted through the mouth or nose into the trachea to facilitate the delivery of oxygen and anesthetic gases. This particular tube is crafted from a special thermo-sensitive, kink-resistant material that softens at body temperature, conforming to the patient's anatomy for enhanced comfort and fit. The "Plain" designation signifies that it does not have a cuff, making it suitable for short-term intubation procedures where long-term mechanical ventilation is not required. It is intended for single use and is provided in a sterile, peelable blister pack.
Thermo-sensitive Material: The tube is made from a material that adapts to the body's natural curves at body temperature, which helps to minimize trauma during intubation. Uncuffed Design: As a "plain" tube, it lacks an inflatable cuff, which is often preferred for short-term airway management. Radiopaque Line: A radio-opaque line runs the entire length of the tube, allowing for clear visualization and confirmation of its position via X-ray. Murphy Eye: The distal end features a smoothly finished Murphy eye, which provides an alternate pathway for airflow if the primary opening becomes occluded. Standard Connector: The proximal end is equipped with a universal 15 mm connector, ensuring compatibility with standard ventilation and anesthesia equipment. Smooth, Bevelled Tip: The naso-oral tip is designed to be smooth and rounded to reduce the risk of injury to the vocal cords and surrounding tissues during insertion. Kink-Resistant Construction: The transparent material is designed to resist kinking, helping to maintain a patent airway.
Q: What is the material of this endotracheal tube?
A: The tube is made from a medical-grade, thermo-sensitive material, often PVC, which softens at body temperature to conform to the patient's airway.
Q: Is this tube sterile and for single use?
A: Yes, the Polymed Endotracheal Tube is supplied sterile in an individually sealed peelable blister pack and is intended for single use only to prevent cross-contamination.
Q: What does 'Plain' signify in the product name?
A: The term 'Plain' indicates that the endotracheal tube is uncuffed, meaning it does not have an inflatable cuff at the distal end.
Q: Does this tube have a Murphy Eye?
A: Yes, the tube is designed with a Murphy eye at the distal end to ensure continuous airflow and reduce the risk of occlusion.
Q: Can the tube's position be verified by X-ray?
A: Yes, it is equipped with a radio-opaque line along its entire length, which allows for easy detection and confirmation of its placement on an X-ray.
Patient Comfort: The thermo-sensitive material softens to conform to the patient's respiratory tract, improving the overall fit. Procedural Accuracy: The integrated radiopaque line and graduation marks aid clinicians in achieving precise placement of the tube. Airway Patency: The presence of a Murphy eye ensures that airflow can continue even if the main lumen is blocked by mucus or the tracheal wall. Versatile Intubation: The design of the tip is suitable for either nasal or oral intubation procedures. Reduced Trauma: The smooth, atraumatic tip and Murphy eye are designed to minimize tissue damage during both intubation and extubation.
This product is intended for use by trained healthcare professionals only. The procedure generally involves pre-oxygenating the patient. Using a laryngoscope, the professional visualizes the vocal cords to guide the tube's insertion through the mouth or nose into the trachea. The tube is advanced until it is properly positioned, with placement often confirmed by observing chest rise, auscultation, and potentially an end-tidal CO2 monitor. Once placement is confirmed, the tube must be secured in place using appropriate medical tape or a commercial tube holder.
It is imperative that this device is used only by qualified medical personnel trained in airway management techniques. Improper insertion or maintenance can lead to complications such as airway injury, infection, or tube dislodgement. The tube's position should be regularly monitored to prevent accidental migration or extubation. Before the procedure, inspect the patient's mouth for any debris or secretions and remove them. This is a sterile, single-use device; do not reuse or re-sterilize.
Store in a cool, dry place, away from direct sunlight. The product is sterile and comes individually packaged in a peelable blister pack. Material: Medical-grade thermo-sensitive material. This is a plain, uncuffed endotracheal tube.
The contents of this website are for informational purposes only and not intended to be a substitute for professional medical advice, diagnosis, or treatment. Please seek the advice of a physician or other qualified health provider with any questions you may have regarding a medical condition. Do not disregard professional medical advice or delay in seeking it because of something you have read on this website.